Table 3

The effect of MA-TCK26D6 on standard coagulation parameters in plasma of thromboembolism-induced mice

Plt (109/L)Fbg (g/L)aPTT (s)PT (s)FVII (%)FVIII (%)
Baseline 316 ± 39 1.35 ± 0.06 20 ± 2 12 ± 0 67 ± 9 41 ± 10 
MA-T30E5A2 39 ± 4* NC NC NC 61 ± 4 7 ± 1* 
MA-TCK26D6 64 ± 9* NC NC NC 66 ± 9 11 ± 5* 
Plt (109/L)Fbg (g/L)aPTT (s)PT (s)FVII (%)FVIII (%)
Baseline 316 ± 39 1.35 ± 0.06 20 ± 2 12 ± 0 67 ± 9 41 ± 10 
MA-T30E5A2 39 ± 4* NC NC NC 61 ± 4 7 ± 1* 
MA-TCK26D6 64 ± 9* NC NC NC 66 ± 9 11 ± 5* 

Data are mean ± SD (n = 5). Baseline levels were obtained by saline injections. Mouse plasma was collected 15 minutes after thromboplastin or saline injections: 26 mg/kg MA-T30E5A2 or 26 mg/kg MA-TCK26D6 was administered before thromboplastin injection.

Plt indicates blood platelets; Fbg, mouse fibrinogen; aPTT, activated partial thromboplastin time; PT, prothrombin time; FVII and FVIII, coagulation factors VII and VIII, respectively; and NC, no coagulation.

*

Significantly different (P < .001) from baseline levels.